In libraryOrion XS 1400 12/24V 50A DC-DC Charger
The Victron Orion XS 1400 is a 1400W DC-DC charger designed for dual-battery systems. It operates within a 9-35V input range and offers a configurable 10-35V output voltage. This charger is suitable for mixed-voltage systems and can also function as a DC-to-DC converter.
We earn a small commission on purchases through this link. It does not change what you pay and never affects ratings.
Safety notes for this component
- Install the product in a heatproof environment, keeping heat-sensitive objects away.
- Ensure a low-impedance GND connection to the vehicle's chassis, free of paint.
- Use flexible multi-stranded copper cables for connections.
- The installation must include a fuse in accordance with recommendations, with a minimum cable gauge of 16 mm2 / 6AWG for lengths <5m.
- Mount the charger close to the battery but never directly above it to prevent damage from battery gassing.
Try it with your setup
How long it takes to charge
At 50 A into a 12 V bank, hours of driving from 20 % to full.
| 100 Ah bank | 1.8 h |
| 200 Ah bank | 3.5 h |
| 300 Ah bank | 5.3 h |
| — |
Datasheet charge current, charge losses and the absorption phase included.
Fine-tune in the charge time calculator →Wiring it in
Current, fuse and cable size for the Orion XS 1400 12/24V 50A DC-DC Charger at full rated power.
Supply → charger
DC input · 12 V| Cable run (one way) | Cable | Voltage drop |
|---|---|---|
| 1 m | 25 mm² · 4 AWG | 0.6 % |
| 2 m | 25 mm² · 4 AWG | 1.2 % |
| 3 m | 25 mm² · 4 AWG | 1.8 % |
| 5 m | 35 mm² · 2 AWG | 2.2 % |
Charger → battery
DC output · 12 V| Cable run (one way) | Cable | Voltage drop |
|---|---|---|
| 1 m | 25 mm² · 4 AWG | 0.6 % |
| 2 m | 25 mm² · 4 AWG | 1.2 % |
| 3 m | 25 mm² · 4 AWG | 1.8 % |
| 5 m | 25 mm² · 4 AWG | 3 % |
Copper cable at 20 °C, positive and negative conductor, at most 3 % voltage drop. The cable is always rated for the fuse that protects it, and the fuse is sized at 125 % of the current. Input current assumes 98.5 % conversion efficiency. If the manufacturer manual specifies a fuse or cable, follow the manual.
Technical data
Alternatives

- Charge current
- 50 A
- Input
- 12 V DC
- Output
- 12 V DC

- Charge current
- 60 A
- PV input
- up to 145 V
- Output
- 12 V DC

- Charge current
- 50 A
- Input
- 12 V DC
- Output
- 12 V DC

- Charge current
- 40 A
- PV input
- up to 100 V
- Output
- 12 V DC
Ratings & reviews
No ratings yet — be the first to rate this component.
Drop the Orion XS 1400 12/24V 50A DC-DC Charger into your wiring diagram
VoltPlan sizes the cables, picks the fuses and checks the voltages for every component you connect around it.