It's even better as an app.$3.99 $1.99 · Pay once, no subscriptionDownload on the App Store
MultiPlus-II 2x120V 12/3000/120-50 Inverter/Charger (PMP122305102)In library
Victron

MultiPlus-II 2x120V 12/3000/120-50 Inverter/Charger (PMP122305102)

The Victron MultiPlus-II 2x120V 12/3000/120-50 is an inverter and charger with a rated output of 2400W. It operates on a 12V DC input voltage and provides a 120V AC output.

Buy — affiliate linkAdd to my wiring diagram

We earn a small commission on purchases through this link. It does not change what you pay and never affects ratings.

Power
2400 W
Surge
5500 W
Input
12 V DC
Output
120 V AC
!

Safety notes for this component

  • This product may only be installed by a qualified electrical engineer.
  • Connect to a DC system with its own dedicated service or house battery with appropriate fusing and DC wiring gauge.
  • Use copper DC cables with a 90ºC (194ºF) rating.
  • Ensure the use of batteries with adequate capacity, an appropriate DC fuse, and battery cables of sufficient cross-section.
  • The AC input must be protected by a fuse or magnetic circuit breaker rated at 50A or less.

Try it with your setup

What it runs

Against 2400 W continuous and 5500 W surge, one appliance at a time.

Laptop charger65 WRuns
Starlink dish75 WRuns
230 V compressor fridge100 WRuns
Corded power drill600 WRuns
Hair dryer1200 WRuns
Microwave (input power)1200 WRuns
Pod coffee machine1400 WRuns
Induction hob, one zone2000 WRuns
Kettle2000 WRuns

Start-up draw from the appliance type: compressor fridges pull about 5× their running power, motors 3×, pumps 4×.

Size an inverter for several appliances at once →

Wiring it in

Current, fuse and cable size for the MultiPlus-II 2x120V 12/3000/120-50 Inverter/Charger (PMP122305102) at full rated power.

Battery → inverter

DC input · 12 V
Current at rated power
215.1 A
Start-up surge
492.8 A
Fuse
300 A Class T
Cable run (one way)CableVoltage drop
1 m185 mm² · 350 MCM0.3 %
2 m185 mm² · 350 MCM0.7 %
3 m185 mm² · 350 MCM1 %
5 m185 mm² · 350 MCM1.7 %
Other length or voltage? Open the wire gauge calculator →

Copper cable at 20 °C, positive and negative conductor, at most 3 % voltage drop. The cable is always rated for the fuse that protects it, and the fuse is sized at 125 % of the current. Input current assumes 93 % conversion efficiency. If the manufacturer manual specifies a fuse or cable, follow the manual.

Technical data

Cont. output power at 25°C2400 W
Cont. output power at 25°C3000 VA
Cont. output power at 40°C2200 W
Cont. output power at 65°C1700 W
Peak power5500 W
DC Input voltage range9,5 – 17 V
Output voltage: 120 VAC ± 2 %, Frequency: 60 Hz ± 0,1%Output voltage: 120 VAC ± 2 %, Frequency: 60 Hz ± 0,1%
Maximum AC input current50 A
Transfer switch50 A
Zero load power19 W
Maximum battery charge current120 A
Charge voltage 'absorption'14.4 V
Charge voltage 'float'13.8 V
Storage mode13.2 V
AC InputSingle phase: 90-140 VAC 45 – 65 Hz

Ratings & reviews

No ratings yet — be the first to rate this component.

Sign in to rate and comment
Free account — also saves your wiring diagrams.

Drop the MultiPlus-II 2x120V 12/3000/120-50 Inverter/Charger (PMP122305102) into your wiring diagram