SI-ACR Automatic Charging Relay 12/24V 120A (7610)
The Blue Sea Systems SI-ACR Automatic Charging Relay (7610) is a 12/24V DC, 120A relay designed to combine batteries when charging and isolate them when discharging or starting engines. It protects sensitive electronics by isolating house loads during engine cranking and is ignition protected for gasoline-powered boats.
We earn a small commission on purchases through this link. It does not change what you pay and never affects ratings.
Safety notes for this component
- Ensure proper wire sizing to prevent overheating, using the provided chart for charging amps up to 120A.
- The ACR is not intended to carry starting currents; use a battery switching system for emergency starting.
- Connect the GND terminal to DC system ground through a one-amp in-line fuse.
- For start isolation, connect the SI terminal to a line that is positive only when cranking, through a 1-10 amp fuse.
Try it with your setup
How long it takes to charge
At 120 A into a 12 V bank, hours of driving from 20 % to full.
| 100 Ah bank | 42 min |
| 200 Ah bank | 1.5 h |
| 300 Ah bank | 2.2 h |
| — |
Charge current from rated power ÷ voltage, charge losses and the absorption phase included.
Fine-tune in the charge time calculator →Wiring it in
Current, fuse and cable size for the SI-ACR Automatic Charging Relay 12/24V 120A (7610) at full rated power.
Supply → charger
DC input · 12 V| Cable run (one way) | Cable | Voltage drop |
|---|---|---|
| 1 m | 95 mm² · 3/0 AWG | 0.4 % |
| 2 m | 95 mm² · 3/0 AWG | 0.8 % |
| 3 m | 95 mm² · 3/0 AWG | 1.3 % |
| 5 m | 95 mm² · 3/0 AWG | 2.1 % |
Charger → battery
DC output · 12 V| Cable run (one way) | Cable | Voltage drop |
|---|---|---|
| 1 m | 70 mm² · 2/0 AWG | 0.5 % |
| 2 m | 70 mm² · 2/0 AWG | 1 % |
| 3 m | 70 mm² · 2/0 AWG | 1.5 % |
| 5 m | 70 mm² · 2/0 AWG | 2.6 % |
Without a datasheet charge current the output current is rated power ÷ nominal voltage, which can read a little above the label. Copper cable at 20 °C, positive and negative conductor, at most 3 % voltage drop. The cable is always rated for the fuse that protects it, and the fuse is sized at 125 % of the current. Input current assumes 90 % conversion efficiency. If the manufacturer manual specifies a fuse or cable, follow the manual.
Technical data
Alternatives

- Charge current
- 70 A
- Input
- 12 V DC
- Output
- 12 V DC

- Charge current
- 40 A
- PV input
- up to 100 V
- Output
- 24 V DC

- Charge current
- 60 A
- PV input
- up to 145 V
- Output
- 12 V DC

- Charge current
- 50 A
- Input
- 12 V DC
- Output
- 12 V DC